.. highlight:: rst

.. _scautopick:

##########
scautopick
##########

**Phase detection and picking on waveforms.**


Description
===========

scautopick applies threshold monitoring by searching for waveform anomalies in
form of changes in amplitudes. It is applied for detecting phase arrivals
creating :term:`phase picks <pick>` and for measuring related features and
:term:`amplitudes <amplitude>`. The picks and associated amplitudes and
features are typically provided to modules like :ref:`scautoloc` for locating
the source.

.. note::

   Instead of detecting phase arrivals for source location, scautopick
   can also be applied for detecting simple amplitude exceedence applying filters
   like the :py:func:`MAX` filter. Exceedences are reported as picks and can be
   processed further, e.g. by :ref:`scalert`.


Phase Detections
================

scautopick detects phase onsets for generating :term:`picks <pick>`. Initally,
it searches for detections on the waveform streams defined by global bindings.


P picks
-------

A primary detector is applied first. When a detection is found, 'P' is by default
assigned to the guess of the phase type (phaseHint). The actual guess can be configured by
:confval:`phaseHint`. By default the primary detector applies a robust STA/LTA
detector (:py:func:`STALTA` filter) to waveforms for making detections. Other
detection filters and filter chains can be choosen from the
:ref:`list of SeisComP filters <filter-grammar>`. A guess of the pick type may
be defined by :confval:`phaseHint`.

Waveforms are typically :ref:`pre-filtered <filter-grammar>` before the actual
:py:func:`STALTA` filter. Without further configuration a
running-mean highpass, a cosine taper and a Butterworth bandpass filter of
third order with corner frequencies of 0.7 and 2 Hz are applied before the
:py:func:`STALTA` filter. The entire filter sequence is configurable by
:confval:`filter`, module configuration, or :confval:`detecFilter`, binding
configuration.

Once the STA/LTA ratio has reached a configurable threshold (by default 3) for a
particular stream, a :term:`pick` is set to the time when this
threshold is exceeded (pick time) and the picker is set inactive. The picker is
reactivated for this stream once the STA/LTA ratio falls to the value of 1.5 (default).

The trigger thresholds are configurable:

* Trigger on: :confval:`thresholds.triggerOn` in module configuration or
  :confval:`trigOn` in binding configuration,
* Trigger off: :confval:`thresholds.triggerOff`, module configuration or :confval:`trigOff`,
  binding configuration.

Initial detections can be further adjusted by a second-stage phase re-picker
(post picker) as defined by :confval:`picker`. The re-picker should be tuned
carefully and global bindings parameters :confval:`picker.*` should be
configured accordingly.

After having detected a phase, the re-picker will be inactive and accept no further
detection until

* The amplitudes measured after filtering (:confval:`filter` in module configuration
  or :confval:`detecFilter` in binding configuration) fall below the
  :confval:`thresholds.triggerOff` (module configuration) or :confval:`trigOff`
  (binding configuration) and
* Amplitudes, :math:`A_{trigger}`, measured after filtering reach or
  exceed a threshold determined by :math:`T_{minOffset}` (:confval:`thresholds.minAmplOffset`),
  :math:`T_{dead}` (:confval:`thresholds.deadTime`) and the amplitude of the
  previous pick, :math:`A_{prev}`:

  .. math ::

     A_{trigger} \ge T_{minOffset} + A_{prev} * exp\left(-(dt/T_{dead})^2\right)

  if :math:`T_{dead} > 0`. Otherwise:

  .. math ::

     A_{trigger} \ge T_{minOffset}

  Here, :math:`dt` is the time passed since the last pick.
  :math:`T_{minOffset}` (:confval:`thresholds.minAmplOffset`) is typically similar to
  the trigger threshold, :confval:`thresholds.triggerOn` (module configuration) or
  :confval:`trigOn` (binding configuration).


S picks
-------

Based on the inital detection or pick a secondary picker may applied be applied,
e.g., for picking S phases as defined by :confval:`spicker`. The secondary picker
is halted as soon as new detections are made unless :confval:`killPendingSPickers`
is inactive.

As for the re-picker also the spicker should be tuned carefully and global
bindings parameters :confval:`spicker.*` should be set.

.. csv-table:: Second-stage pickers available by configuration of :confval:`picker` or :confval:`spicker`
   :align: center
   :delim: ,
   :widths: 1 3 1 1 3
   :header: "picker name", "phase", "picker", "spicker", "global bindings parameters"

   "AIC", "P, configurable: :confval:`phaseHint`", "x", "", "picker.AIC.*"
   "BK", "P, configurable: :confval:`phaseHint`", "x", "", "picker.BK.*"
   "S-L2", "S", "", "x", "spicker.L2.*"


Feature extraction
------------------

For extracting features related to picks such as polarization parameters
configure :confval:`fx` and the related global bindings parameters :confval:`fx.*`.


Amplitude Measurements
======================

The second task of scautopick is to calculate amplitudes of a given type for the
corresponding magnitude type (see :ref:`scamp` for a list of amplitude types and
:ref:`scmag` for the magnitude types). Such amplitudes are required by:

* :ref:`scautoloc` for associating phase picks and generating a source location
* EEW (earthquake early warning) systems in order to provide rapid amplitudes for
  magnitudes as soon as source locations are available.

The time window for measuring amplitudes starts at the pick time. The window
length is constant and specific to the amplitude type. It can be adjusted in
global bindings. For example mb is calculated
for a fixed time window of 30 s after the pick, mB for time window of 60s, for
MLv a time window of 150 s is estimated to make sure that S-arrivals are inside
this time window. The pre-calculated amplitudes are sent out and received by
the magnitude tool, :ref:`scmag`.
The fixed time window poses a limitation to EEW system. Howver, a speed-up is
available with :confval:`amplitudes.enableUpdate`.
Read the :ref:`scamp` documentation for more details on amplitude measurements.


PublicID Generation
===================

There are two modes of publicID generation of the resulting objects,
:ref:`picks <api-python-datamodel-pick>` and
:ref:`amplitudes <api-python-datamodel-amplitude>`:

1. Generate standard publicIDs based on :confval:`publicIDPattern`. In addition to the
   available pattern tokens, scautopick adds four new tokens: :code:`@net@`,
   :code:`@sta@`, :code:`@loc@` and :code:`@cha@` which are replaced with the
   corresponding identifiers of the stream the pick or amplitude has been declared on.
   Furhtermore the new token :code:`@type@` was added which refers to the processor
   type used to create the pick or amplitude. If a pick is created from a detection
   then the type is "D". For amplitudes the type is effectively the amplitude type,
   e.g. "MLv".
   Example: the pattern :code:`@classname@/@time/%Y%m%d%H%M%S.%f@.@id@/@net@.@sta@.@loc@.@cha@/@type@`
   results in :code:`Pick/20260210.123456.89.321/GE.MORC..BHZ/AIC`.
2. Generate simplified publicIDs as with SeisComP3 with pattern :code:`@time@-@type@-@sid@`.
   Example: :code:`20260210.123456.89-P-GE.MORC..BHZ`. To enable that mode, set
   :confval:`simplifiedIDs` to :code:`true`.


Modes of Operation
==================

scautopick usually runs in the background connected to a real-time data source
such as :ref:`Seedlink <seedlink>`. This is referred to as online mode. Another
option to run scautopick is on offline mode with files.


Real-time
---------

In real-time mode the workflow draws like this:

* scautopick reads all of its binding parameters and subscribes to stations
  defined by global binding parameters where :confval:`detecEnable` is set to ``true``.
* The data time window requested from the data source is [system-:confval:`leadTime`, NULL]
  meaning an open end time that causes :ref:`SeedLink <seedlink>` to stream
  real-time data if no more data are in the buffers.
* Each incoming record is filtered according to :confval:`detecFilter`.
* The samples are checked for exceedance of :confval:`trigOn` and in the positive
  case either a post picker (:confval:`picker`) is launched or a :term:`Pick <pick>`
  object will be sent.
* If :confval:`sendDetections` is set to ``true``, a trigger will be sent in any
  case for e.g. debugging.
* After the primary stage has finished (detector only or picker) secondary
  pickers will be launched if configured with :confval:`spicker`.

These steps repeat for any incoming record.

To run scautopick in the background as a daemon module enable and start it ::

$ seiscomp enable scautopick
$ seiscomp start scautopick

For executing on the command line simply call it with appropriate options, e.g. ::

   $ seiscomp exec scautopick -h


Non-real-time
-------------

.. note::

   Due to code changes in the file data source, the command line option
   :option:`--playback` is essential for non-real-time operation. Otherwise a
   real-time time window is set and all records are most likely filtered out.

To tune scautopick or to do playbacks it is helpful to run scautopick not with
a real-time data source but on a defined data set, e.g. a multiplexed sorted miniSEED
volume. scautopick will apply the same workflow as in online mode but the
acquisition of data records has to change. If the input data (file) has been
read, scautopick will exit and furthermore it must not ask for a particular
time window, especially not for a real-time time window. To accomplish that
the command-line parameter :option:`--playback` has to be used. Example:

.. code-block:: sh

   $ scautopick --playback -I data.mseed

This call will process all records in :file:`data.mseed` for which bindings
exist and **send the results to the messaging**. If all data records are processed,
scautopick will exit. The processing steps are similar to the online mode.

Use the :option:`--ep` for offline processing **without messaging**. The results are
printed in :term:`SCML` format. Example:

.. code-block:: sh

   $ scautopick --playback -I data.mseed --ep -d [type]://[host]/[database] > picks.xml


.. _scautopick_configuration:

Module Configuration
====================

| :file:`etc/defaults/global.cfg`
| :file:`etc/defaults/scautopick.cfg`
| :file:`etc/global.cfg`
| :file:`etc/scautopick.cfg`
| :file:`~/.seiscomp/global.cfg`
| :file:`~/.seiscomp/scautopick.cfg`

scautopick inherits :ref:`global options<global-configuration>`.



.. confval:: ringBufferSize

   Default: ``300``

   Type: *int*

   Unit: *s*

   Defined the record ringbuffer size in seconds.


.. confval:: leadTime

   Default: ``60``

   Type: *int*

   Unit: *s*

   The leadTime defines the time in seconds to start picking on
   waveforms before current time.


.. confval:: playback

   Default: ``false``

   Type: *boolean*

   If enabled, picks can be made on waveforms which are older than
   current time \- \"leadTime\". Current time is the time
   when the module was started. This allows to pick
   historic data in real\-time playbacks which are preserving the
   record times. See e.g. the \"msrtsimul\" module.
   This option deactivates \"leadTime\". Activate only for playbacks.


.. confval:: initTime

   Default: ``60``

   Type: *int*

   Unit: *s*

   The initTime defines a time span in seconds for that the picker
   is blind after initialization. This time is needed to initialize
   the filter and depends on it.


.. confval:: gapInterpolation

   Default: ``false``

   Type: *boolean*

   Interpolate gaps linearly? This is valid for gaps shorter
   than thresholds.maxGapLength.


.. confval:: useAllStreams

   Default: ``true``

   Type: *boolean*

   If enabled, all streams that are received by the picker are
   used for picking. This option has only effect if a
   file is used as input which contains more data than the
   picker requests. If connected to a waveform server such as
   SeedLink, the picker will only receive the data it is
   subscribed to.


.. confval:: filter

   Default: ``"RMHP(10)>>ITAPER(30)>>BW(4,0.7,2)>>STALTA(2,80)"``

   Type: *string*

   The default filter used for making detections. Station\-specific
   configurations \(bindings\) override this value.


.. confval:: timeCorrection

   Default: ``-0.8``

   Type: *double*

   Unit: *s*

   The time correction applied for a pick. Station\-specific
   values \(bindings\) override this value.


.. confval:: picker

   Type: *string*

   Values: ``AIC,BK,GFZ``

   The re\-picker to use. By default only simple detections
   are emitted as picks. To enable re\-picking on a time window around
   the detection, an algorithm \(plugin\) can be defined with this parameter.
   
   More options may be available by plugins. Configure related
   parameters in global bindings.


.. confval:: phaseHint

   Default: ``P``

   Type: *string*

   Phase hint to be assigned to the pick made by the primary picker.


.. confval:: sendDetections

   Default: ``false``

   Type: *boolean*

   If enabled and \"picker\" is configured, then
   initial detections are sent as well. To distinguish between
   detections and picks the evaluation status of the pick is
   set to \"rejected\". This is meant to be a debug
   option which can be used to compare detections and picks by
   their evaluation status.


.. confval:: spicker

   Type: *string*

   Values: ``S-L2,S-V``

   The secondary picker to use, e.g., for picking S\-phases.
   
   More options may be available by plugins. Configure related
   parameters in global bindings.


.. confval:: killPendingSPickers

   Default: ``true``

   Type: *boolean*

   If enabled, all secondary pickers that were triggered by
   a previous pick will be terminated when a new detection or
   pick has been found. This aims to avoid the case where an
   S phase is wrongly picked as P but would also be picked as
   S by the secondary picker. But suppressing the S pick can
   lead to undesired results. It might be better in some
   situations to have two picks \(P and S\) instead only a wrong P.


.. confval:: extraPickComments

   Default: ``false``

   Type: *boolean*

   If enabled and \"picker\" or \"spicker\" is
   configured, extra comments will be added to the resulting pick.
   
   Supported comments:
   
   SNR: added if SNR >\= 0, comment id is \"SNR\"
   
   duration: added if the duration has been computed at the time
   of the pick creation, which actually requires
   \"thresholds.maxDuration\" to be configured
   with a non\-negative value.


.. confval:: simplifiedIDs

   Default: ``false``

   Type: *boolean*

   If enabled then simplified pick and amplitude IDs will be created.
   Rather than the configured publicID pattern, the following pattern
   will be used: \"%Y%m%d.%H%M%S.%f\-\@net.sta.loc.cha\@\".


.. confval:: fx

   Type: *string*

   Values: ``DFX``

   Configures the feature extraction type to use. Currently
   available: \"DFX\". Configure related parameters
   in global bindings.
   
   When configured, the usability of the features for locating
   events depends on the used locator, e.g. LOCSAT will by default
   consider slowness and backazimuth when measured. Read the
   locator's documentation and configuration parameters.


.. confval:: amplitudes

   Default: ``MLv, mb, mB``

   Type: *list:string*

   The amplitude types to be computed by the picker based on
   picks.


.. note::
   **thresholds.\***
   *Threshold parameters for the primary picker.*



.. confval:: thresholds.triggerOn

   Default: ``3``

   Type: *double*

   For which value on the filtered waveforms is a pick
   detected. Station specific values override this value.


.. confval:: thresholds.triggerOff

   Default: ``1.5``

   Type: *double*

   The value the filtered waveforms must reach to enable
   detection again. Between triggerOn and triggerOff the
   picker is blind and does not produce picks. Station
   specific values override this value.


.. confval:: thresholds.maxGapLength

   Default: ``4.5``

   Type: *double*

   Unit: *s*

   The maximum gap length in seconds to handle.
   Gaps larger than this will cause the picker to be reset.


.. confval:: thresholds.amplMaxTimeWindow

   Default: ``10``

   Type: *double*

   Unit: *s*

   The time window used to compute a maximum \(snr\) amplitude
   on the filtered waveforms.


.. confval:: thresholds.deadTime

   Default: ``30``

   Type: *double*

   Unit: *s*

   The time used together with measured amplitude and
   `thresholds.minAmplOffset` for scaling the amplitude below which
   the picker is inactive after a P pick. Read the documentation\!


.. confval:: thresholds.minAmplOffset

   Default: ``3``

   Type: *double*

   The amplitude used together with measured amplitude and
   `thresholds.deadTime` for scaling the amplitude below which
   the picker is inactive after a P pick. The value is typically
   similar to the trigger threshold. Read the documentation\!


.. confval:: thresholds.minDuration

   Default: ``-1``

   Type: *double*

   Unit: *s*

   The minimum duration to reach. The duration is measured as
   the time between trigger on and trigger off. If this value
   is configured, the detection \(pick\) will be delayed in order
   to compute and check the duration.
   
   The duration will be reported as comment to the pick when
   activating \"extraPickComments\" allowing the tuning
   of the acceptable duration range.


.. confval:: thresholds.maxDuration

   Default: ``-1``

   Type: *double*

   Unit: *s*

   The maximum duration allowed. The duration is measured as
   the time between trigger on and trigger off. If this value
   is configured, the detection \(pick\) will be delayed in order
   to compute and check the duration. Negative values
   deactivate the check.
   
   The duration will be reported as comment to the pick when
   activating \"extraPickComments\" allowing the tuning
   of the acceptable duration range.


.. confval:: amplitudes.enableUpdate

   Type: *list:string*

   Configure a list of magnitude types.
   Update and send amplitudes for these magnitudes as soon as data are
   available. Do not wait for complete time windows.
   Only magnitudes computed by scautopick as given by the amplitudes parameter are considered.
   This option is for rapid magnitude estimation and EEW.
   
   WARNING: This option increases the load on the system\!


.. confval:: connection.amplitudeGroup

   Default: ``AMPLITUDE``

   Type: *string*

   Message group for sending amplitudes to.


.. note::
   **comment.\***
   *Properties of a custom comment added to a pick. It requires both*
   *ID and text to be configured.*



.. confval:: comment.ID

   Type: *string*

   The ID of a custom comment.


.. confval:: comment.text

   Type: *string*

   The text of a custom comment.



Bindings Parameters
===================



.. confval:: detecEnable

   Default: ``true``

   Type: *boolean*

   Enables\/disables picking on a station.


.. confval:: detecFilter

   Default: ``"RMHP(10)>>ITAPER(30)>>BW(4,0.7,2)>>STALTA(2,80)"``

   Type: *string*

   Defines the filter to be used for picking.


.. confval:: trigOn

   Default: ``3``

   Type: *double*

   For which value on the filtered waveform is a pick detected.


.. confval:: trigOff

   Default: ``1.5``

   Type: *double*

   The value the filtered waveform must reach to
   enable a detection again.


.. confval:: timeCorr

   Default: ``-0.8``

   Type: *double*

   Unit: *s*

   The time correction applied to a pick.


.. confval:: sensitivityCorrection

   Default: ``false``

   Type: *boolean*

   Defines whether the detector applies sensitivity correction
   \(applying the gain\) or not in advance to filter the data.




Command-Line Options
====================

.. program:: scautopick


Generic
-------

.. option:: -h, --help

   Show help message.

.. option:: -V, --version

   Show version information.

.. option:: --config-file file

   The alternative module configuration file. When this option
   is used, the module configuration is only read from the
   given file and no other configuration stage is considered.
   Therefore, all configuration including the definition of
   plugins must be contained in that file or given along with
   other command\-line options such as \-\-plugins.

.. option:: --plugins arg

   Load given plugins.

.. option:: -D, --daemon

   Run as daemon. This means the application will fork itself
   and doesn't need to be started with \&.

.. option:: --auto-shutdown arg

   Enable\/disable self\-shutdown because a master module shutdown.
   This only works when messaging is enabled and the master
   module sends a shutdown message \(enabled with
   \-\-start\-stop\-msg for the master module\).

.. option:: --shutdown-master-module arg

   Set the name of the master\-module used for auto\-shutdown.
   This is the application name of the module actually
   started. If symlinks are used, then it is the name of
   the symlinked application.

.. option:: --shutdown-master-username arg

   Set the name of the master\-username of the messaging
   used for auto\-shutdown. If \"shutdown\-master\-module\" is
   given as well, this parameter is ignored.


Verbosity
---------

.. option:: --verbosity arg

   Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
   4:debug.

.. option:: -v, --v

   Increase verbosity level \(may be repeated, e.g., \-vv\).

.. option:: -q, --quiet

   Quiet mode: no logging output.

.. option:: --component arg

   Limit the logging to a certain component. This option can
   be given more than once.

.. option:: -s, --syslog

   Use syslog logging backend. The output usually goes to
   \/var\/lib\/messages.

.. option:: -l, --lockfile arg

   Path to lock file.

.. option:: --console arg

   Send log output to stdout.

.. option:: --debug

   Execute in debug mode.
   Equivalent to \-\-verbosity\=4 \-\-console\=1 .

.. option:: --log-file arg

   Use alternative log file.


Messaging
---------

.. option:: -u, --user arg

   Overrides configuration parameter :confval:`connection.username`.


.. option:: -H, --host arg

   Overrides configuration parameter :confval:`connection.server`.


.. option:: -t, --timeout arg

   Overrides configuration parameter :confval:`connection.timeout`.


.. option:: -g, --primary-group arg

   Overrides configuration parameter :confval:`connection.primaryGroup`.


.. option:: -S, --subscribe-group arg

   A group to subscribe to.
   This option can be given more than once.

.. option:: --content-type arg

   Overrides configuration parameter :confval:`connection.contentType`.

   Default: ``binary``


.. option:: --start-stop-msg arg

   Default: ``0``

   Set sending of a start and a stop message.


Database
--------

.. option:: --db-driver-list

   List all supported database drivers.

.. option:: -d, --database arg

   The database connection string, format:
   service:\/\/user:pwd\@host\/database.
   \"service\" is the name of the database driver which
   can be queried with \"\-\-db\-driver\-list\".

.. option:: --config-module arg

   The config module to use.

.. option:: --inventory-db arg

   Load the inventory from the given database or file, format:
   [service:\/\/]location .

.. option:: --db-disable

   Do not use the database at all


Records
-------

.. option:: --record-driver-list

   List all supported record stream drivers.

.. option:: -I, --record-url arg

   The RecordStream source URL. Format:
   [service:\/\/]location[#type].
   \"service\" is the name of the RecordStream driver
   which can be queried with \"\-\-record\-driver\-list\".
   If \"service\" is not given, \"file:\/\/\" is
   used and simply the name of a miniSEED file can be given.

.. option:: --record-file arg

   Specify a file as record source.

.. option:: --record-type arg

   Specify a type for the records being read.


Mode
----

.. option:: --offline

   Do not connect to a messaging server and do not use the database.

.. option:: --playback

   Switches to playback mode which does not request a particular time window from
   the input data source. This implies that all records are forwarded to scautopick
   if files are being used. Without this option scautopick sets the requested
   start time to NOW\-leadTime and therefore would not work anymore with
   older datasets in offline mode or when running playbacks.

.. option:: --ep

   Outputs an XML event parameters file containing all
   picks and amplitudes. This option implies '\-\-offline'.
   Consider '\-\-playback' or configure accordingly for
   processing data from the past.

.. option:: --amplitudes arg

   Default: ``1``

   Enables or disables computation of amplitudes.

.. option:: --test

   Runs the picker as usual but does not send any messages. This can be useful to
   test the picker within a running system.

.. option:: --dump-config

   Dumps the current configuration and exits. Station configuration is only read if
   the picker connects to the messaging and the database. In offline mode it will
   only dump the application specific setting unless a station.conf file is provided.

.. option:: --dump-records

   This option only works in combination with :option:`\-\-offline`. It will dump
   the data of an amplitude processor if it completed processing successfully
   and a new amplitude is available. The output format is a simple ASCII format.


Settings
--------

.. option:: --filter filter

   Overrides configuration parameter :confval:`filter`.


.. option:: --time-correction time

   Overrides configuration parameter :confval:`timeCorrection`.


.. option:: --buffer-size timespan

   Overrides configuration parameter :confval:`ringBufferSize`.


.. option:: --before timespan

   Overrides configuration parameter :confval:`leadTime`.


.. option:: --init-time timespan

   Overrides configuration parameter :confval:`initTime`.


.. option:: --trigger-on arg

   Overrides configuration parameter :confval:`thresholds.triggerOn`.


.. option:: --trigger-off arg

   Overrides configuration parameter :confval:`thresholds.triggerOff`.


.. option:: --trigger-dead-time arg

   Overrides configuration parameter :confval:`thresholds.deadTime`.


.. option:: --ampl-max-time-window arg

   Overrides configuration parameter :confval:`thresholds.amplMaxTimeWindow`.


.. option:: --min-ampl-offset arg

   Overrides configuration parameter :confval:`thresholds.minAmplOffset`.


.. option:: --gap-tolerance arg

   Overrides configuration parameter :confval:`thresholds.maxGapLength`.


.. option:: --gap-interpolation arg

   Overrides configuration parameter :confval:`gapInterpolation`.


.. option:: --any-stream arg

   Overrides configuration parameter :confval:`useAllStreams`.


.. option:: --send-detections

   Overrides configuration parameter :confval:`sendDetections`.


.. option:: --extra-comments

   Overrides configuration parameter :confval:`extraPickComments`.



Output
------

.. option:: -f, --formatted

   Use formatted XML output along with '\-\-ep'. Otherwise XML
   is unformatted.